 Safety Relays
Timing Control Units
CU4 Specifications
Standards EN 954-1, ISO 13849-1, IEC/EN 60204-1, IEC 60947-5-1, ANSI B11.19, AS4024.1 Cat. 3 per EN 954-1 (ISO13849-1) C-Tick, CE marked for all applicable directives, cULus and BG 24V AC/DC, 50/60 Hz 0.85 to 1.1 x rated voltage 2.5W 1 N.C. or 2 N.C. Infinite 2 N.O. Safety; 1 N.C. Auxiliary B300 AC-15 5A/250V AC, 5A/125V AC N300 DC-13 3A/24V DC 0.15 to 30s 6A Slow Blow or 10A Quick Blow 10mA/10V Ag Sn O2/0.5 Au 30msec Green = Power Green =CH t1 Active Green = CH t2 active 2500V 2 -5C to +55C (+23F to 131F) 90% RH IP40 (NEMA 1) IP20 0.2-4mm2 (24-12AWG) 0.4Nm (3.54lbin) 35mm DIN rail 165g (0.36lbs) 100,000 operations 500,000 operations 1,000,000 operations 2,000,000 operations 2,000,000 operations 10-55 Hz, 0.35mm 10g, 16ms, 100 shocks
Category Approvals Power Supply Power Consumption Safety Inputs Input Simultaneity Outputs Output Utilization per IEC 60947-5-1 (Inductive)
Description
The CU4 is an off-delay timing unit which can be operated standalone or as an extension of a host relay. The timed outputs are used in applications where power must be maintained for a fixed duration after an input signal is received. For example, driving a power to lock TLS2-GD2 to maintain a guard door in the locked position for a fixed duration after a stop button is pressed. Another example would be maintaining the connection of a drive to a motor until the braking function is achieved, and then dropping out a contactor to remove power to the motor. The inputs can be connected in either a single channel or dual channel configuration. The inputs must remain closed during the complete timing cycle. Opening the contacts before the timing cycle completes causes the timer to be reset to zero. The CU4 has a redundant structure with two independent safe timer circuits. The outputs include two normally open safety delayed outputs as well as one normally closed safety output. The safety outputs have independent and redundant internal contacts to help ensure the safety function. When used an extension of a host relay, the normally closed contacts should be used in the feedback loop of the host relay. If used in standalone application, the normally closed contacts can be used to signal an auxiliary device or PLC. A typical operation starts with power applied to A1/A2 and the input circuits open. 1. Close the B11/B12 and B21/B22 circuits. a. The safety outputs (17/18 and 27/28) close immediately. 2. Open the B11/B12 or B21/B22 circuits. a. The timing process starts. b. The safety outputs (17/18 and 27/28) open after the time expires. 3. Go to Step 1.
Timed Off-Delay Fuses Output External Min. Switched Current/Voltage Contact Material Response Time Indication LEDs Impulse Withstand Voltage Pollution Degree Operating Temperature Humidity Enclosure Protection Terminal Protection Maximum Conductor Size Torque Settings--terminal screws Mounting Weight Electrical Life 220V AC/4A/880VA cos=0.35 220V AC/1.7A/375VA cos=0.6 30V DC/2A/60W 10V DC/0.01A/0.1W Mechanical Life Vibration Shock
Features
* * * * * * Category 3 per EN 954-1 Stop category 1 Timed off-delay 0.15s to 30s 2 Safety contacts 1 Auxiliary contact 1 Monitoring contact
See Output Ratings on page 1-29 for details. Consult factory for ratings not shown.
4-64
Safety Relays
Timing Control Units
CU4 Product Selection
Inputs Safety Outputs Auxiliary Outputs Timing Range 0.15 - 3s 1 N.C. or 2 N.C. 2 N.O. 1 N.C. 0.5 - 10s 1.5 - 30s Catalogue Number 440R-S23173 440R-S23174 440R-S23175
Dimensions--mm (inches) Block Diagram
22.5 (0.88) 75.0 (2.95)
A1 35 K1 K2 36 18
17 B11 17 27
27 B12 35
110 (4.33)
18 28 B21 28
36 B22 A2
Typical Wiring Diagrams
Aux Circuit
81 K1 L1 L2 L3 A1 B11 B21 17 27 35
A1
E-Stop
A1 S11 S12 S21 S22 S23 X2 13 23 33 43 53
Solenoid
42 41 12 22 34
Aux Circuit
54 53 33
+24V DC
MSR124RT
A2 PE Y1 Y2 X5 X6 X1 14 24 34 44 54 82
K2
CU4
A2
M
A2
B12 B22 18
28
36
11
21
Reset
K1 K2
TLS2-GD2 Power to Lock
Ground
Dual Channel Wiring to CU4 Inputs
Aux Circuit
81 K1 L1 L2 L3 A1 B11 B21 17 27 35
A1
E-Stop
A1 S11 S12 S21 S22 S23 X2 13 23 33 43 53
Solenoid
42 41 12 22 34
Aux Circuit
54 53 33
+24V DC
MSR124RT
A2 PE Y1 Y2 X5 X6 X1 14 24 34 44 54 82
K2
CU4
A2
M
A2
B12 B22 18
28
36
11
21
Reset
K1 K2
TLS2-GD2 Power to Lock
Ground
Single Channel Wiring to CU4 Inputs
4-65